Mueller Super Centurion®
![public://uploads/media/super_centurion_render_clr_img_0.jpg](https://muellercompany.com/sites/muellercompany.com/files/styles/product_main_image/public/uploads/media/super_centurion_render_clr_img_0.jpg?itok=kePq0B6v)
Mueller Super Centurion®
Features:
- 2-way, 3-way, and 4-way Hydrant: maximum working pressure 350psig/24barg (2400kPa); Test pressures 700psig/48barg (4800kPa).
- UL Listed and FM approved. UL 246 and FM 1510 specifications. (CE marked to EN14384 available).
- Meets or exceeds all applicable requirements of ANSI/AWWA C502 and certified to ANSI/NSF 61/372.
- O-ring sealed Bonnet, Ground, and Shoe Flange – better leak resistance, easier maintenance.
- Stem - E-Coated for Corrosion Resistance.
- O-ring sealed Oil Reservoir with Filler Plug – permits easy check of oil level and refill without removing Bonnet; filled at factory.
- Automatic operating mechanism lubrication – positive lubrication of stem threads and bearing surfaces each time hydrant is operated.
- Full flow performance – large radius Hose and Pumper openings and conical Upper Valve Plate reduce turbulence and provide low friction loss.
- Bury Depth Tag - Attached to the Chain, provides instant Bury-Depth information.
- Field replaceable, O-ring sealed Hose and Pumper Nozzles – threaded in place and retained by Stainless Steel locks – NST or BSP threads. Integral Storz connectors also available to order.
- O-ring sealed Bronze Seat Ring – Resists corrosion and easily removed for maintenance through top of hydrant.
- Traffic Flange and Stainless Steel Stem Coupling – if Hydrant is struck, Flange and Coupling break free preventing damage to Stem and Main Valve, and uncontrolled Water flow – Coupling will not break into pieces that could drop down and affect Valve operation. Reusable Clip is easy to use. Repair is simple and economical.
- Patented Reversible, Encapsulated Compression-Type Main Valve - closes with pressure for positive seal. Rubber material has long service life, yet is reversible, providing a convenient spare in the Hydrant.
- Double Bronze Drains – each time Main Valve opens or closes, Drain Valves force-flush drain openings to keep them open for Barrel drainage.
- Inlet Connections: 6”/DN150 Flanged ANSI B16.1 Class 125 Flat Face (optional PN10, PN16 drilling). Mechanical Joint and other Inlet Connections available.
Resources:
- Datasheet
- Brochure
- Brochure (Spanish)
- Operating Instructions - Super Centurion 250
- Operating Instructions - Super Centurion 250 (Spanish)
- Operating Instructions - Super Centurion 350
Videos:
Mueller® Hydrant Safety Flange
Mueller Fire Hydrant Plant - Albertville, AL
Centurion® 250 Hydrant Features
Centurion® Hydrant Maintenance and Repair
Main Valve Rebuild
Hydrant Extension
Hydrant Safety Flange
Hydrant Nozzle
Hydrant Fill Oil
Hydrant Facing